myDatalogC3

Switch cabinet controller for telecontrol, automation and control

The myDatalogC3 enables data acquisition, communication and control in the control cabinet. The data will be transferred to the platform. Basic software is available for the application logic. Via the graphical, user-friendly interface, the device. Alternatively, you can program your own applications and thus adapt the myDatalogC3 to your individual needs.

  • Reliable real-time data connection
  • 27 industrial interfaces (mA, digital) for data acquisition from analog and digital sensors as well as signal transmitters
  • Modbus RS485, RS232 and CAN bus interfaces for seamless communication with machines, control units and sensors
  • Relay outputs for control and telecontrol
  • PLC, router and firewall for secure data transmission and protection against unauthorized access
  • Efficient data transmission with cellular (2G, 3G, 4G, M1/NB1), WiFi and LAN

All-in-one ecosystem

PLC, router, firewall and data transmission to the web platform are integrated in myDatalogC3. This ensures secure data transmission and protects information from unauthorized access. Due to the coordinated overall system, process-related requirements are already implemented and the integration of the solution is minimal.

rapidM2M C3 - All in One SPS, Router, Firewall

Easy configuration, maximum flexibility

The channels and alarm thresholds are easily configured via the graphical interface on the platform. In addition, you benefit from evaluation and reporting functions. To customize the application to your specific requirements, programming with extensive libraries is possible in the studio.

IoT im Schaltschrank

Industrial interfaces

The interfaces are remotely configurable (universal input (4-20mA), RS232, RS485, CAN). This ensures the greatest flexibility. The device is perfectly applicable in automation, control and remote action. The two relays are individually configurable. Sensors are integrated in a few minutes.

rapidM2M C3 extension

Expansion modules for more inputs/outputs

With the input extension myDatalogC3e 12UI/2Rel the base unit gets additional twelve universal inputs as well as two potential-free switch contacts for controlling actuators. The output extension myDatalogC3e 3mA/6Rel expands by three analog outputs and six relays.

Remotely configure, control and evaluate

Easy implementation and convenient operation

With the pre-installed software, the basic functionalities are parameterized user-friendly and graphically on the platform.

Basic functions of the software for myDatalogC3 (optional with extension modules):

  • Recording of all channels
  • Configurable recording interval
  • Constant online connection possible
  • Configurable warning, alarm and trigger thresholds for inputs
  • Alarm in case of supply voltage failure

Central management

Alerts, dashboards, reports & updates

The platform allows you to create alerts, dashboards and reports within minutes. Updates to firmware, applications and configurations are conveniently carried out remotely via the web login – without having to travel to the unit.

Integration into further systems is easily possible via the web interfaces (RESTful API or OPC-UA). This allows, for example, a direct coupling into process control systems.

For solution experts from the industry

Customization for your applicative needs

For specific adaptation of the application to your requirements, the myDatalogC3 is customizable in the studio with many libraries. Create your own remote controls, monitoring and alerts.

Industrial Onboarding makes the first steps easier for you. For one day, our experts with many years of experience will help you with. You will get to know the myDatalogC3 in the free programming option. Together you collect, process and transmit the data from your signalers. You take the programmed myDatalogC3 home with you at the end of the onboarding.

Modbus RTU/ASCII

Microtronics Modbus Master Library

The Modbus master library currently supports the master mode for serial interfaces (RS232 and RS485) and is characterised by its universal applicability. In addition, great importance was attached to easy integration into own projects during the development. Zudem steht der vollständige Sourcecode im Studio zur Verfügung. The data transmission can be carried out either in the efficient Modbus-RTU or alternatively in the Modbus-ASCII format. You can find out more here.

Upcoming: Standard software for Modbus configuration. Ask your Partner Manager for more details.

Product configurator

Runtime Calculator

Starting Position Designed for permanent connection to the server (operating mode "Online"), measurement interval 1sec

Battery life in years

0
calculating...

Recommended tariff

calculating...
With the runtime calculator you can estimate the autonomous runtime of the application as well as the costs incurred. The actual costs and energy consumption depend on the measurement conditions, such as the reception quality and ambient temperature. Detailed information on the tariffs can be found here.

With the help of the runtime calculator, you can estimate the autonomous runtime of the application as well as the costs incurred. The actual costs and energy consumption depend on the measurement conditions, such as the reception quality and ambient temperature. Detailed information on the tariffs can be found here.

Technical data

myDatalogC32x myDatalogC33x
Distinguishing features Standard applications with 3 MB flash memory Data memory (512 MB Flash, 8 MB RAM, 128 kb FRAM)
additional connectivity via WiFi & a network interface
Item no. The variants differ in data transmission

301293 LTE-M1/NB1
301294 2G/3G/4G World
301331 WiFi/2G/3G/4G World
Inputs 3x analogue or digital
and
12x analogue or digital (input extension)
Input configuration
  • 0...20mA / 4...20mA
  • 0...2V / 0...10V
  • PWM
  • Frequency
  • Digital / Counter
Measuring range / resolution
  • 0...20mA / 4...20mA: 6.3µA, load 96R
  • 0...2V: 610µV
  • 0...10V: 7.97mV
  • PWM: 100Hz
  • Frequency: 1kHz
  • Digital: 100ms
  • Counter: 1ms
Temperature sensor
Internal sensors and measured values
  • Input voltage
  • Mobile strength
  • WiFi field strength
  • Temperature in the device
Serial interfaces, bus interfaces
  • 1x RS232
  • 1x RS485
  • 1x CAN
Outputs
  • 2x relay
  • 6 x relay and 3 x analogue (output extension)
Power supply 9...32VDC
Protection class IP20 / IP40 (connection area / actuation area)
Display RGB-LED
Dimensions 70 x 92 x 63mm (without antenna), 4DU
Data transmission Optional:
  • LTE M1/NB1
  • LTE 2G/3G/4G
WiFi/2G/3G/4G
Name Hardware Version Document Category Revision
Fact Sheet myDatalogC32x 2G/M1/NB1 World from Hw 1.2 Fact Sheet 04
Fact Sheet myDatalogC32x M1/NB1 EU from Hw 1.2 Fact Sheet 05
Fact Sheet myDatalogC32x 2G/3G/4G World from Hw 1.2 Fact Sheet 05
Fact Sheet myDatalogC33x WIFI/3G World from Hw 1.2 Fact Sheet 04
Fact Sheet myDatalogC33x WIFI/2G/4G EU from Hw 1.2 Fact Sheet 04
Fact Sheet myDatalogC33x WIFI/2G/3G/4G World from Hw 1.2 Fact Sheet 05
Manual myDatalogC32x from Hw 1.2 Manual 06
Manual myDatalogC33x from Hw 1.2 Manual 06
EU Declaration of Conformity myDatalogC32x M1/NB1 EU from Hw 1.2 EU Declaration of Conformity 22.09.2023
EU Declaration of Conformity myDatalog C3xx WIFI/2G/3G/4G World from Hw 1.2 EU Declaration of Conformity 22.9.2023
3D View myDatalogC3xx from Hw 1.2 3D View Hw 1.2
Voltage AC Voltage DC Current AC Current DC Rated surge voltage
myDatalogC3 Relay Mode 32V 32V 2A 2A 1.5kV
Impulse Mode 32V 32V 0.13A 0.13A
Input extension Relay Mode 230V 220V 2A 2A
Impulse Mode 230V 230V 0.13A 0.13A
Output extension Relay Mode 230V 30V 3A / relay
6A for common CC
3A / relay
6A for common CC
2.5kV

Product variations

ProducttitlemyDatalogC3
Item no. myDatalogC3
Power supply 9...32VDC, from 0.9W, nominal 5W
Data memory myDatalogC32x:
  • 3MB internal flash memory
myDatalogC33x:
  • 512 MB flash (file system, 3 MB for measurement data)
  • 8 MB RAM
  • 128kB FRAM
Programming In Studio with C-like scripting language built on PAWN
Dimensions 70 x 92 x 63mm (without antenna)
Protection class IP20 / IP40 (connection area/operating area)
Operating temperature -20...+60°C
Inputs

3 x analogue or digital (individually configurable per channel)

  • 0...20mA / 4...20mA
  • 0...2V / 0...10V
  • PWM
  • Frequency
  • Digital / Counter

Resolution
  • 0...20mA / 4...20mA: 6,36µA
  • 0...2V: 610µV
  • 0...10V: 7,97mV
Outputs 2 x Relay (with parallel pulse relay for setpoint output to, for example, dosing pumps; each channel can be configured individually)
Serial interfaces

1 x RS485 (2-Leiter)

1 x CAN / CAN FD

1 x RS232 (4-Leiter)

Data transmission myDatalogC32x:
  • Mobile radio optional:
    • 2G/M1/NB1 World
    • M1/NB1 EU
    • 3G World
    • 2G/4G EU
    • 2G/3G/4G World
myDatalogC33x:
  • Mobile radio optional:
    • 2G/3G World
    • 2G/4G Europe
    • 2G/3G/4G World
  • WiFi:
    • Single band 2,4 GHz
    • IEEE 802.11 b/g/n
  • Network interfac:
    • 10/100 Ethernet
SIM integrated SIM chip
Positioning by using GSM cell location
base price-
  

Do you want more infos about myDatalogC3?

Stefan Pfeffer

To load the content, please click on the button. By doing so, you agree to the loading of HubSpot cookies. You can find out more in our privacy policy.

Load content

Request a quote for a device/application

Tell us about your application.
We will be happy to assemble the device according to your requirements.

To load the content, please click on the button. By doing so, you agree to the loading of HubSpot cookies. You can find out more in our privacy policy.

Load content

In order to use our live chat, you must agree to the loading of Hubspot cookies. You can find out more about this in our privacy policy.