[cb_product_intro_img]
myDatasensH2S

Effective monitoring of hydrogen sulphide

The myDatasensH2S continuously measures the H2S concentration in the air. The data logger is designed for the operation in harsh environments such as sewers and wastewater treatment plants and is certified for operation in ATEX Zone 1. The measurement data is stored on the web platform. The battery life is up to 36 months due to the Ultra Low Power technology.
Actively combat the smell of harmful hydrogen sulphide and the corrosion of components. Make better data-driven decisions by permanently recording H2S levels. Optimise the use of chemicals and expand the application with automated dosing control. In targeted measurement campaigns over a representative period, you can determine the load for the dimensioning of future systems or for improvements to the existing duct system.

Innovative sensor exchange for seamless data acquisition

Old H2S sensor out, new H2S sensor in - thanks to the magnetic contact, correct insertion is guaranteed. While the new H2S sensor is busy measuring, the old H2S sensor is recalibrated and then used again. In this way, you save costs, time and resources and enjoy the advantage of seamless data acquisition.

myDatasens - Measuring device for measuring and transmitting gas values in the ATEX zone

ATEX Zone 1

The myDatasensH2S is certified for use in the potentially explosive area of ATEX Zone 1. The data is transmitted via mobile radio directly from the ATEX zone to the central web platform.

myDatasensH2S colour display

Full colour display

The 1.5" full colour OLED display shows the current measured values as well as status information such as the time until the next calibration and service directly on site without additional software.

myDatasensH2S rubber armour

Robust and resistant

With the rubber armour, the device is well protected for the harsh environment for which it was designed. All parts on the unit are made of plastic to prevent corrosion from the extremely aggressive gases. Repairability and inexpensive spare parts ensure cost-efficient operation.

What we offer

The new generation of H2S measurement

  • Measurement and monitoring of H2S
  • Data recording without data holes
  • Operating times of at least 24 months
  • Quick and efficient sensor replacement
  • Inexpensive spare parts
  • Economical use of resources
  • Robust devices

You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.

More Information

You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.

More Information

H2Sand NH3

Choosing the right sensor

What is the difference between nominal and maximum value? What is the resolution and zero offset? What range will your readings be and what accuracy do you need?

The Microtronics team will be happy to advise you on the selection of the right sensor for your application.

Sensor as a Service

Increase measurement quality

To increase the measurement quality of your campaigns, professional calibration of the sensors every six months is essential. “Sensor as a Service” provides you with the required gas sensors and includes sensor preparation and replacement.

With the brand new GasBuster App you can comfortably read out the current values at the site. H2S concentration and temperature are displayed in the app. Swipe to switch between all sensors within your reach. The GasBuster communicates with your smarphone via BLE. You can synchronize the data to the server via the GSM of your smartphone. Depending on the frequency of the measurement site visits the values are available on the server worldwide. GasBuster is available for Android and iOS.

 

Apple iStore Button   Google Play Button

Runtime Calculator

Starting Position Measurement interval 1min, transmission interval 4h

Battery life in years

0 17
calculating...

Recommended tariff

calculating...
With the runtime calculator you can estimate the autonomous runtime of the application as well as the costs incurred. The actual costs and energy consumption depend on the measurement conditions, such as the reception quality and ambient temperature. Detailed information on the tariffs can be found here.

Technical specifications

ProducttitlemyDatasensH2S1000
Item no. myDatasensH2S1000
Ex certification

Optional:

  • Zone 1 (<Ex> II 2G Ex ib IIB T3 Gb)
  • non ATEX

Power supply Battery
Battery Life Time

Gateway:

  • BLE-Variant: Devices lifetime long runtime at 1min measurement cycle
  • BLE/3G-Variant: 5 years at 1min measurement cycle and 4h transmission cycle
  • BLE/LTE-M-Variant: Devices lifetime long runtime months at 1min measurement cycle and 4h transmission cycle

Sensor: 24 months

Data memory Internal flash memory for up to 82.776 measurement cycles
Dimensions 106 x 169 x 61mm (with protective armour)
Protection class

Complete system: IP66

Gateway: IP66 / IP68 / IP69

(IP68: max. immersion depth 1m for max. 5h )

Sensor: IP66

Meaning of IP protection classes

Operating temperature -20...+50°C
Display 1,5" Full Color Display, Resolution 128 x 128
Number of sensors 1 x H2S 7H Sensormodul
Sensor module

H2S Gas Nominal: 0-200ppm, Peak Load: 1000ppm

Resolution: 0,25ppm, Accuracy: 1%, T 90  Time: <=35s, Abrasion: 0 ... 100%

Measurement range gateway

Internal Temperature: -20...+60°C

Internal Air Humidity: 0...100% rH

Battery SOC (State of Charge): 0 ... 100%

BLE Signal Quality: -50dBm ... -110dBm

GSM Signal Quality: -50dBm ... -110dBm

Measurement method electrochemical gas sensor
Temperature sensor

Measurement range: -20...+50°C

Resolution: 0,1°C

Data transmission

  • Bluetooth Low Energy (Range up to 20m; depending on conditions)
  • 2G/3G Europe (Optional)
  • LTE-M Europe (optional)

SIM integrated SIM chip
Positioning for the 3G variant by using GSM cell location